The measuring range from 100 uOhm to 40 ohm makes it possible to measure the
resistance of motor coils, generators and transformers as well as switches,
relays and contacts. The 4-wire measuring method allows resistance values in
the milliohm range to be measured precisely and, for example, the quality of
plug-in and screw connections to be assessed.
Milliohm measuring ranges: 400 mOhm/4/40 Ohm
Test current: 200 mA/ 20 mA/ 2 mA
Voltage measurement: 1000 V AC/DC
Current measurement: 400 mA AC/DC
Resistance measurement up to 40 mOhm
Capacitance measurement up to 40 mF
Diode and continuity test function
El. safety: EN-61010-1 CAT III 1000 V
4-pole Kelvin test leads, test leads with 2 mm tips, case and operating instructions